- Product of Canada
- UL Listed
- Available with Hard Wire and Multiplex

Control Unit

MMX 2003-12N

  • One expandable to 9 circuits (SLC)
  • Multiplex fire alarm control panel
  • For small to medium and industrial occupancies
  • control up to 63 nodes
  • support 99 analog sensors 
  • support 99 addressable modules
  • 4 status queues with selector switches and LEDS
  • auxiliary relay contacts
  • false alarm prevention technology

Control Unit

MMX2009-12NDS

  • One expandable to 17 Circuits (SLC)
  • Multiplex fire alarm control panel
  • For small to medium and industrial occupancies
  • control up to 63 nodes
  • support 99 analog sensors 
  • support 99 addressable modules
  • 4 status queues with selector switches and LEDS
  • auxiliary relay contacts
  • false alarm prevention technology

Control Unit

MR 2312 DDR

  • hard-wire fire alarm control panel
  • control up to 12 zones
  • LCD display, integrated UDACT/digital communicator
  • confiquralbe onsite and through PC
  • configurable signal silence inhibit, auto signal silence and one-man walk test
  • subsequent alarm, supervisory and trouble operation

Fire Detection

MMX 2009/12NDS

  • Multiplex fire alarm control panel
  • For small to medium and industrial occupancies
  • control up to 63 nodes
  • support 99 analog sensors 
  • support 99 addressable modules
  • 4 status queues with selector switches and LEDS
  • auxiliarz relaz contacts
  • false alarm prevention technology

Heat Detector

5601P, 5604

  • fixed temp and combination fixed-temp. /rate of rise 57.2°C or 90°C ratings
  • operating humidity range:5 – 95% RH non-condensing
  • back box mounting options: 
    single gang – 3.5″ and 4″
    octagonal – 4″

Heat Detector

MRI-5251B

  • 57°C fixed and rate-of-rise thermal detection
  • Relative humidity: 10% – 93%, non-condensing
  • mounting options:
    single gang 3,5″ 
    octagonal  4″
    square 4″ with 3″ mud ring

Smoke Detector

MRI-2251

  • intelligent addressable  photoelectric smoke detector
  • ULC, UL, CSFM, MSFM and MEA listed
  • Temp.range MRI-2251: 0°- 49°C
  • sealed against dirt, bugs and back pressure

SmokeDetector

SD-2WD-LED

  • photoelectric smoke detectors
  • UL listed
  • 2-wire model
  • smoke  sensitivity: 2.66 +/- 1.11! FT obscuration
  • detection range 50 foot rating for heat sensor
  • temperature rage -10° to + 50°C

Manual Station

MRM-710

  • manual station
  • dual action: “PUSH BAR” and “PULL HANDLE”
  • key resettable
  • ADA 5 lb. max. manual-force
  • mounts
    – single gang box
    – metal back box
    – weather proof backbox

Manual Station

MRM-MPG1

  • manual station
  • single action “pull”
  • resettable with screw driver
  • standard single gang mount

Bell

6"

  • bell 6″
  • operate on 24 VDC and motor driven
  • sound output 82 dBA

Module

MRI M502

Module

MRI M500s

Module

MRI M500x

Module

MRI M501